The primary mission of the Basalt & Rural Fire Protection District is to provide emergency and non-emergency services for the protection of life and property in Pitkin and Eagle County, Colorado. The department provides 24-hour emergency response to a wide variety of critical situations, including fires, explosions, hazardous materials incidents, medical emergencies, accidents and miscellaneous public assistance requests. In addition, the department operates active fire prevention and emergency preparedness programs which provides for fire inspections, hazardous process permitting, fire code enforcement, community education and business emergency planning in accordance with Colorado laws.

Contact Us

1089 JW Drive
Carbondale, CO 81623
970-704-0675
info@basaltfire.org

Fire Extinguishers

While fire extinguishers are an important part of fighting small fires, you should fight a fire with a fire extinguisher only when all of the following are true:

  • Everyone has left or is leaving the building.
  • The fire department has been called.
  • The fire is small and confined to the immediate areas where it started such as in a wastebasket, cushion, small appliance, stove, etc.
  • You can fight the fire with your back to a safe escape route.
  • Your extinguisher is rated for the type of fire you are fighting and is in good working order.
  • You have had training in use of the extinguisher and are confident that you can operate it effectively.

Remember, if you have the slightest doubt about whether or not to fight the fire – DON’T. Instead, get out, closing the door behind you to slow the spread of the fire. You have a well trained and equipped fire department standing by ready to protect you. They are professionals, let them do their job.

Fire extinguishers are not designed to fight a large or spreading fire. Even against small fires, they are useful only under the right conditions.An extinguisher must be large enough for the fire at hand. It must be available and in working order, fully charged. The operator should be familiar with the extinguisher so it won’t be necessary to read directions during an emergency.

A fire extinguisher should be “listed” and “labeled” by an independent testing laboratory such as FM (Factory Mutual) or UL (Underwriters Laboratory).The higher the rating number on an A or B fire extinguisher, the more fire it can put out, but high-rated units are often the heavier models. Make sure you can hold and operate the extinguisher you are buying.

Remember that extinguishers need care and must be recharged after every use. Ask the dealer about the extinguisher and how it should be serviced and inspected. A partially used unit might as well be empty.

You may need more than one extinguisher in your home. For example, you may want an extinguisher in the kitchen as well as one in the garage or workshop. Each extinguisher should be installed in plain view near an escape route and away from potential fire hazards such as heating appliances.

Types of Fire Extinguishers

Type A

A Type A label is in a triangle on the extinguisher. This extinguisher is used for ordinary combustibles such as cloth, wood, rubber and many plastics. These types of fire usually leave ashes after they burn. Remember: Type A extinguishers for Ashes.

Type B

A Type B label is in a square on the extinguisher. This extinguisher is used for flammable liquid fires such as oil, gasoline, paints, lacquers, grease, and solvents. These substances often come in barrels. Remember: Type B extinguishers for Barrels.

Type C

A Type C label is in a circle on the extinguisher. This extinguisher is used for electrical fires such as in wiring, fuse boxes, energized electrical equipment and other electrical sources. Electricity travels in currents. Remember: Type C extinguishers for Currents.

Type D

A Type D label is in a star on the extinguisher. This extinguisher is used for metal fires such as magnesium, titanium and sodium. These types of fire are very dangerous and seldom handled by the general public. Remember: Type D for Don’t Get Involved.

Pictograms

Recently, pictograms have come into use on fire extinguishers. These picture the type of fire on which an extinguisher is to be used. For instance, a Type A extinguisher has a pictogram showing burning wood. A Type C extinguisher has a pictogram showing an electrical cord and outlet. These pictograms are also used to show what not to use. For example, a Type A extinguisher will show a pictogram of an electrical cord and outlet with a big slash through it. In other words, this extinguisher should not be uses on an electrical fire.

Number Rating

Fire extinguishers also have a number rating. For Type A fires, a 1 would stand for 1 1/4 gallons of water, a 2 would represent 2 1/2 gallons, 3 would be 3 3/4 gallons of water, etc. For Type B and Type C fire, the number represents square feet. For example, 2 would be two square feet, 5 is five square feet, etc.

Fire extinguishers can also be made to extinguish more than one type of fire. For example, you might have an extinguisher with a label that reads 2A5B. This would mean this extinguisher is good for Type A fires with a 2 1/2 gallon equivalence and it is also good for Type B fires with a 5 square feet equivalency. A good extinguisher to have in each residential kitchen is a 2A10BC fire extinguisher. You might also want to get a Type A for the living room and bedrooms and an ABC for the basement and garage.

Using A Fire Extinguisher

There are four simple steps to using a fire extinguisher. A simple acronym to remember to operate most fire extinguishers is PASS. PASS stands for Pull,Aim,Squeeze and Sweep.

Pull the pin at the top of the cylinder. Some units require the releasing of a lock latch or pressing a puncture lever.

Aim the nozzle at the base of the fire.

Squeeze or press the handle.

Sweep the contents from side to side at the base of the fire until it goes out.

Shut off the extinguisher and then watch carefully for any rekindling of the fire.

Roaring Fork Fire & EMS

Member Login:
Login:
Password:
We use Aladtec for online scheduling

Wildfire Information

Check out the links below for valuable resources and information regarding wildfire preparedness and education.

Pitkin County Wildfire

Fire Chief's Video

Fire Ban Questions

The fire district is located in both Eagle and Pitkin Counties. The responsibility of initiating or rescinding fire bans falls to the sheriffs of both of these counties. Please direct any questions you may have to the Sheriff’s office in your county. To obtain a burn permit please go here.


Eagle County Sheriff's Office
(970) 328-8500


Pitkin County Sheriff's Office
(970) 920-5300